EICR electricians · landlords, agents and homeowners
Put through to aqualified EICRelectrician near you.
Not every electrician inspects. We send one who does: qualified in inspection and testing, carrying calibrated kit, at a fixed price agreed before anyone books a visit.
Fixed price
From £75
Report
Within 48 hours
Inspector
Qualified to test
N E SE SW W NW B M LS S NG CV BS L CF MK BN PL OX CB RG GU NE YO LE DE SO PO HU EX
Your postcode
e.g. LS6 2AB
That doesn’t look like a UK postcode. Try the first half, like LS6 or SW11.
Or dial direct
Type a postcode and press Connect me. We’ll show you what to say when you ring and what it costs. Or ring now: 020 3386 1854.
Putting you through to {pc}…
Line open for {pc}. Ring 020 3386 1854 and say “EICR, {pc}”. We’ll tell you on the call whether an inspector covers {pc}, the earliest date, and the fixed price: £75 for a studio, £98.99 for 1–3 bedrooms.
Line cleared. Type another postcode, or ring 020 3386 1854.
Every electrician wires. Fewer inspect.
An EICR isn’t installation work. It is a periodic inspection: a full check and test of wiring someone else put in, written up to BS 7671. The rules for rented homes say it must be done by a person qualified and competent to inspect and test. Switch between the two to compare.
The installing electrician
- Fits new sockets, lights, circuits, consumer units and rewires.
- Signs off their own new work with an EIC or a minor works certificate.
- May be registered to self-certify Building Regulations (Part P) work.
- Doesn't necessarily hold an inspection and testing qualification, or do periodic reports regularly.
- Good for the repairs after an EICR. Not automatically the right person for the report itself.
The inspecting electrician
- Holds an inspection and testing qualification such as City & Guilds 2391, or 2394 plus 2395.
- Works to the current BS 7671 and the IET guidance on periodic inspection.
- Uses calibrated test instruments for continuity, insulation resistance, loop impedance and RCD tests.
- Writes the full report: schedule of inspections, schedule of test results and coded observations.
- Is the person the regulations mean by "qualified and competent". This is who we send.
EICR
Electrical Installation Condition Report: the result of a periodic inspection of existing wiring, with every finding coded.
EIC
Electrical Installation Certificate: issued for new installations, rewires and new circuits.
MEIWC
Minor Electrical Installation Works Certificate: for small jobs such as an extra socket on an existing circuit.
Six questions to ask any electrician before they book
Whoever you call, us included, these are the questions that separate a proper inspection from a quick walk-round. Open each line to hear the answer you want, and the answer you’ll get from us.
“Which inspection and testing qualification do you hold?”
The answer you want
City & Guilds 2391 (inspection, testing and certification), or 2394 and 2395, or an equivalent EAL qualification, plus the current BS 7671 qualification. “I’ve been an electrician for years” doesn’t answer the question.
Our answer
We send inspectors qualified in inspection and testing, working to the current BS 7671. Ask on the phone which qualification they hold and who is coming, and ask to see the certificate.
“Which scheme are you registered with, and what's the number?”
The answer you want
A full-scope competent person scheme or registration body, with a registration number you can look up yourself. Industry guidance for landlords (Electrical Safety Roundtable, June 2025) lists this check.
Our answer
The inspector’s scheme number is yours on request, before the visit, so you can check it on the register.
“How long will you be at the property?”
The answer you want
Hours, not minutes. Every circuit is isolated and tested in turn, so a flat usually takes 1.5–2.5 hours and a 2–3 bed house 2.5–4 hours. Thirty minutes for a house means circuits weren’t tested.
Our answer
We give you an estimate of time on site when we quote, so your tenant knows how long the power will be off and on.
“What exactly will I receive, and when?”
The answer you want
The full EICR: the summary and overall assessment, the schedule of inspections, the schedule of test results for every circuit, and each observation with its code. A one-page “certificate” alone isn’t the report.
Our answer
The complete report as a PDF within 48 hours of the visit, ready to send to your tenant, agent or council.
“Is the price fixed, and are repairs quoted separately?”
The answer you want
A fixed price for the inspection before the visit, and any repairs priced separately afterwards, with no pressure to book them on the day. You can use any qualified electrician for the repairs.
Our answer
Fixed price from £75, confirmed in writing before we book. Repairs quoted separately; you’re free to use anyone.
“Are you insured for inspection work?”
The answer you want
Yes, with public liability and professional indemnity insurance. The same industry guidance lists both. Ask any firm to email the documents before the visit and keep them with the report.
Our answer
Ask us on 020 3386 1854 and we’ll send the inspector’s details with your booking confirmation.
Look them up before they knock
Five minutes on the register tells you more than any website badge. This works for any electrician you’re thinking of booking, and it’s what a council would expect a careful landlord to have done.
electricalcompetentperson.co.uk
Business name or postcode
Business name
Example Electrical Ltd
Trading address
1 Example Street, Anytown
Scheme
Competent person scheme
Registration no.
000000
Registered for
Domestic installation (Part P)
Inspection and testing? Ask.
Ask for the scheme and the number on the phone. They are what you search with.
Screenshot saved today
Illustration of a typical entry. Names and numbers are examples.
Ask for the scheme and the number
On the phone, ask which competent person scheme or registration body the inspector belongs to, and their registration number.
A firm that hesitates or “will send it later” hasn’t answered.
Ask for the scheme and the number on the phone. They are what you search with.
Search the register
Go to electricalcompetentperson.co.uk (England and Wales) or the scheme’s own register. Search by business name or postcode.
The main electrical schemes list their registered firms on it.
Search the register by business name or postcode, or use the scheme’s own search.
Match the details
The business name, trading address and registration number should match what you were told. A different name can mean a subcontractor, so ask who is actually coming.
Name, trading address and number should all match what you were told on the phone.
Check what they're registered for
Registration for installing (Part P work) is not the same as competence in periodic inspection. Ask directly whether inspection and testing is within their assessed scope.
Registration usually covers installation work. Ask directly whether inspection and testing is in their assessed scope.
File it with the report
Save a screenshot of the register entry with the date, and keep it with the EICR. If a council ever asks how you chose the inspector, it’s one page.
Save a dated screenshot of the entry and keep it with the EICR.
Government guidance for landlords points to the Registered Competent Person Electrical register and to Electrical Safety First’s “find a registered electrician” search. Keep a note of what you checked: it’s part of showing you took reasonable steps.
Source: GOV.UK, Electrical safety standards in the private and social rented sectors: guidance (updated Nov 2025).
When to hang up
Cheap reports cost landlords twice: once for the report a council won’t trust, then again for a proper one. These are the signs on the call or in the report that something is off. Heard any of these on a call, or spotted them in a report? Tick them for a straight answer.
A price far below everyone else's
Testing every circuit takes hours. A price far below the market usually means the testing doesn’t happen.
A report promised before the visit
“We’ll have it to you tonight” before anyone has seen the consumer unit is a certificate, not an inspection.
Under an hour on site
Ask your tenant how long they stayed. Isolating and testing each circuit can’t be done in a quick walk-round.
No schedule of test results
A real EICR lists readings for every circuit. Blank columns, or the same reading copied down the page, mean nothing was measured.
No registration number on request
Anyone competent to inspect can tell you where they’re registered. If they can’t, you can’t show the council they were qualified.
Everything coded C2, and sign today
Pressure to agree a large repair bill on the spot is a reason to pause. Ask what each code is for and get a second quote.
Limitations that cover most of the house
Some limits are normal, such as a sealed-off loft. A report that leaves out whole floors or most circuits doesn’t show the installation is safe.
Nobody can say who's coming
You should know the inspector’s name before the day, and your tenant should be able to check their ID at the door.
Call check
No warning signs yet
Tick anything you’ve heard or seen. No ticks is what you want from any electrician, us included.
Ask before you book
One sign on its own can have a fair answer. Ask the firm to explain it, and check them on the register.
Get a second quote
Two signs together usually mean corners will be cut somewhere. Compare with a fixed quote that says what is tested.
Hang up
Several signs together usually mean a walk-round sold as an EICR, and a report a council won’t trust. Book someone else.
or call 020 3386 1854
Ask us all six questions. We'll answer on the call.
Who's calling? We'll put you through.
Landlord, agent, homeowner or buyer: an EICR electrician near you does the same tests for everyone, but the rules, deadlines and price depend on who you are. Pick yours.
Landlord in England
The Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020
You need
An EICR by a qualified and competent person, before a new tenancy starts and at least every 5 years, or sooner if the report says so.
Copies
Existing tenants within 28 days of the inspection; new tenants before they move in; the council within 7 days if it asks.
If it fails
Remedial or further investigation work within 28 days (or less if the report says), then written confirmation to the tenant and council within 28 days of the work.
Penalty
Up to £40,000 per breach since the 2025 amendment.
Our price
£75 for a studio, £98.99 for 1–3 bedrooms, fixed.
5 yrs
between inspections, at most
28 days
to send tenants a copy, and to fix C1, C2 and FI
£40,000
maximum penalty per breach
HMO landlord
Same regulations, plus your licence conditions
You need
An EICR covering the whole building, including common parts, at least every 5 years. Many councils ask for it with a licence application.
Watch for
Licence conditions can ask for certificates to be sent when they’re renewed. Check your licence wording.
Extra time
More circuits, landlord’s supply, fire alarm and emergency lighting circuits. Allow half a day to a full day on site.
Our price
Priced on the call, after a few questions about rooms and common parts.
5 yrs
whole building, common parts included
½–1 day
usual time on site
On the call
fixed after a few questions
Letting agent
Booking on behalf of a landlord
You need
One contact for access, a fixed price your landlord approves before the visit, and the PDF report to forward the same day it arrives.
Good practice
Diary the 28-day tenant copy deadline from the inspection date, not the report date.
Several lets
Call with the list of addresses and sizes and we’ll price each one.
Our price
Per property, from £75.
28 days
tenant copy, counted from the inspection
48 hrs
full PDF report after the visit
From £75
per property, fixed
Landlord in Wales
Renting Homes (Wales) Act 2016 and fitness regulations
You need
An EICR at least every 5 years for occupation contracts, by a qualified person.
Copies
To the contract-holder within 14 days of occupation (changed from 7 days in 2022).
Check
Rent Smart Wales registration and licensing are separate duties.
5 yrs
between inspections, at most
14 days
copy to the contract-holder
From £75
studio or 1-bed, fixed
When you ring, just say
“EICR for an occupation contract in Wales, postcode CF24.”
Homeowner
No legal duty, good reasons to check
Suggested
The IET recommends a periodic inspection of an owner-occupied home at least every 10 years, and when the occupier changes.
Good times
Before renovating, after a flood or fire, if fuses keep tripping or you see scorch marks, and before an older relative moves in.
Our price
The same fixed bands as rentals: from £75.
10 yrs
IET recommendation for your own home
48 hrs
full PDF report after the visit
From £75
same fixed bands as rentals
When you ring, just say
“EICR for my own home, built in the 1970s, postcode BS7.”
Buying or selling
A homebuyer survey isn’t an electrical test
Buying
Surveyors note what they can see. An EICR tests what they can’t, and C1 or C2 findings can help you negotiate before exchange.
Selling
Having a recent report ready answers a common question on the property information form before a buyer asks.
Timing
Book as soon as an offer is accepted; access is easier before the move.
Pre-exchange
book as soon as an offer is accepted
48 hrs
full PDF report after the visit
From £75
fixed before we book
Holiday let owner
Not covered by the tenancy rules, still on you
Why
Short lets aren’t tenancies, but you have a duty of care to guests, insurers may ask for an EICR, and many booking platforms ask hosts to confirm safety checks.
Timing
Book it into a changeover gap or the quiet season so no nights are lost.
Our price
Same fixed bands, by number of bedrooms.
5 yrs
the interval many owners follow
Off-season
book it into a changeover gap
From £75
by number of bedrooms
Dial the deadlines
The landlord rules in England come down to six numbers. Put your finger in a hole and turn: the dial takes you to the rule behind it.
Landlord deadlines
ENGLAND
Day 0
Inspected before the tenancy starts
A new tenancy can’t begin unless the installation has been inspected and tested. A valid report from the last 5 years covers this; you don’t need a fresh EICR for every new tenant.
Reg 3(1)(c), S.I. 2020/312
Day 0
5 years
Inspected at least every 5 years
Or sooner, if the last report sets an earlier date. The interval runs from the date of the inspection.
Reg 3(1)(b) and 3(2)
5 yrs
28 days
A copy to existing tenants
Each existing tenant gets a copy within 28 days of the inspection. New tenants get one before they move in; prospective tenants within 28 days of asking in writing.
Reg 3(3)(b) and 3(3)(e)
28 d
7 days
A copy to the council, if it asks
If the local housing authority asks in writing for the report, it must have it within 7 days of the request.
Reg 3(3)(c)
7 d
28 days
Repairs, then written confirmation
C1, C2 and FI items must be dealt with within 28 days, or the shorter time on the report. Then written confirmation from the electrician goes to the tenant and council within 28 days of the work.
Reg 3(4) and 3(5)
Fix 28
£40,000
The maximum penalty per breach
Councils can impose a financial penalty of up to £40,000 for each breach, up from £30,000 since the 2025 amendment. They can also arrange remedial work and recover the cost.
S.I. 2025/1043, amending S.I. 2020/312
£40k
What the electrician actually does
An EICR is mostly testing, and testing means switching circuits off. This is the order of a proper visit, and why each part matters to you.
ID shown
ID, the scope and the limits
The inspector shows photo ID, then agrees with you or your tenant what’s being inspected and anything that can’t be reached, such as a boarded loft. Those are written into the report as limitations.
Why it matters: limitations are the first thing to read on any EICR.
arrival
ID shown
Visual inspection
Consumer unit, cables, sockets, switches, light fittings, bathrooms, earthing and bonding to gas and water pipes. Signs of heat, damage, DIY work and missing covers.
Why it matters: many C2 findings, such as missing bonding, are found by looking.
visual check
Look before test
Continuity of protective conductors
Checks that the earth path is unbroken from the board to every point, and that ring circuits really are complete rings.
Why it matters: a broken earth looks fine until something goes wrong.
continuity test
Ω R1+R2
Insulation resistance
A test voltage is applied between conductors to find damaged or deteriorating cable insulation, usually reported in megohms.
Why it matters: low readings point to damage, damp or ageing cable before it shows.
insulation test
MΩ at 500 V
Polarity
Confirms switches and protective devices are in the line conductor, not the neutral, so “off” really means off.
Why it matters: reversed polarity can leave a light fitting live when switched off.
polarity
L / N correct
Earth fault loop impedance
Measures whether enough current would flow in a fault to trip the fuse or breaker fast enough, compared with the limits in BS 7671.
Why it matters: this is the test that shows protection would actually work.
loop impedance
Zs in Ω
RCD tests
Each RCD is tripped with a test instrument and its trip time recorded. The test button on the device is pressed too.
Why it matters: missing RCD protection where it’s needed is one of the most frequent findings.
RCD test
Trip time ms
The report is written
Every reading goes into the schedule of test results, every finding gets a code, and the installation is marked satisfactory or unsatisfactory overall.
Our promise: the full report as a PDF within 48 hours.
the report
PDF in 48 h
Read the codes on your report
Old switchboards had indicator panels that showed which line needed attention. Your EICR works the same way: every finding gets one of four codes. Press a code, or pick a finding from your report to see which code it usually gets.
Danger present
Potentially dangerous
Further investigation
Improvement recommended
Press a code
Each one opens to show what the code means, what you have to do, and by when. Any C1, C2 or FI makes the whole report unsatisfactory.
C1: Danger present
Risk of injury now. Immediate action is needed.
What you do
Make safe straight away. Most inspectors isolate or make safe with your agreement before leaving. Permanent repair within 28 days at the latest.
Typical examples
Exposed live parts, burnt or melted accessories.
Overall
Report is unsatisfactory.
C2: Potentially dangerous
Not dangerous this minute, but could become so in a fault.
What you do
Urgent remedial work within 28 days, or less if the report says.
Typical examples
Missing main bonding, loop impedance too high, no earth to metal light fittings.
Overall
Report is unsatisfactory.
FI: Further investigation
Something needs looking into that couldn’t be resolved on the day.
What you do
Investigate within 28 days, or less if stated, then fix whatever it finds.
Typical examples
Low insulation readings with no obvious cause, circuits that can’t be traced.
Overall
Report is unsatisfactory.
C3: Improvement recommended
Doesn’t meet the current edition, but isn’t unsafe.
What you do
No legal deadline. Worth planning in, for example with other work.
Typical examples
Missing labels, older but sound wiring and accessories.
Overall
On its own, the report can still be satisfactory.
What does your report say?
Choose a common finding…
C1 | Exposed live parts (broken socket, missing cover) | Exposed live parts, such as a broken socket or missing consumer unit cover
C1 | Burning or scorch marks | Signs of burning or overheating at a socket or the consumer unit
C2 | No RCD on sockets used for outdoor equipment | No RCD protection on sockets likely to power equipment outdoors
C2 | Missing main bonding to gas or water | Main protective bonding missing or undersized at the gas or water pipe
C2 | Loop impedance too high | Earth fault loop impedance too high for the protective device
C2 | No earth to metal light fittings | No protective (earth) conductor on a lighting circuit with metal fittings
FI | Low insulation reading, cause unknown | Insulation resistance readings low on a circuit; cause not found
FI | Untraceable circuit | Circuit could not be traced or its purpose identified
C3 | Missing circuit labels | Consumer unit labelling missing or incomplete
C3 | Older but safe wiring | Older installation not to the current edition but not dangerous
Codes are the inspector’s judgement on your installation. If a code surprises you, ask which regulation it refers to. That’s a fair question and any good inspector will answer it.
The tariff, fixed before we book
Prices go by the size of the property, plus £89.99 for each extra consumer unit, and we confirm the exact figure in writing before the visit. It doesn’t change on the day.
Studio flat
Usually 1.5–2.5 hours on site
£75
1–3 bedroom home
Usually 2–4 hours on site
£98.99
4 bedroom home
Usually 4–5 hours on site
£109.99
5–6 bedroom home
Usually 5–7 hours on site
£149.99
HMO
Half a day to a full day, common parts included
On the call
Commercial unit, up to 10 circuits
£15 for each extra circuit
£149.99
Each extra consumer unit (fuse board) is £89.99, or £129.99 on a commercial EICR. Parking or congestion charges may apply where relevant. Repairs are never bundled in: if the report needs work, it’s quoted separately and you can use any qualified electrician. A consumer unit replacement starts from £650.
How long will yours take?
Tell us a little about the property. The price goes by its size, plus £89.99 for each extra consumer unit; the time shows how long the power will be going on and off, so you can warn your tenant.
Roughly when was it last rewired?
Consumer units (fuse boxes)
£98.99
£89.99
about 3 hours
half a day to a full day
The price is confirmed in writing before booking and doesn’t change on the day.
Each extra consumer unit adds £89.99 and time on site; outbuildings and older wiring add time only. The price is confirmed in writing before booking.
HMOs vary with rooms and common parts, so we confirm the exact figure on the call before booking.
Before you ring, have these to hand
A two-minute call gets you a fixed price and a date. Tick what you’ve got and watch the call ticket fill in.
The postcode and address
So we can tell you straight away whether an inspector covers it.
Postcode + address
Bedrooms, and whether it's a house, flat or HMO
That sets the fixed price band.
Bedrooms / type
Who will let the inspector in
Your tenant’s number or the agent’s, if you won’t be there.
Tenant contact
The date of the last report, if any
And a copy if you have it: previous limitations help.
Last EICR date
Where the consumer unit is
Cupboard, cellar or communal meter room, and whether it needs a key.
Board location
Parking
Permit zone, visitor bays or a driveway: the inspector carries heavy kit.
Parking notes
Call ticket
To: 020 3386 1854 · EICR quote
Nothing ticked yet. You can still ring without any of it.
READY TO RING
After the report, three lines out
Whatever the report says, it sends you down one of three lines. None of them requires using the same electrician.
Your EICR
Overall: satisfactory or unsatisfactory
Satisfactory: file it
Send copies to your tenants within 28 days, keep it until the next inspection, and diary the next date (5 years, or sooner if the report says).
C2 or FI: 28 days
Get the work done within 28 days or the shorter period on the report, by any qualified person. Then send written confirmation to the tenant and council within 28 days of finishing.
C1: made safe now
Danger present. Most inspectors will make it safe or isolate it with your agreement before leaving, and tell you and the occupier. The permanent repair follows.
What counts as “written confirmation”
A new satisfactory EICR, an Electrical Installation Certificate, or a Minor Works certificate from the person who did the repair. GOV.UK guidance lists all three.
Some repairs need Part P sign-off
In England, a new circuit, a replacement consumer unit or a rewire is notifiable. A registered installer self-certifies it; otherwise building control must be involved.
A second opinion is allowed
You can get the repairs quoted by another qualified electrician. We quote ours separately and never as a condition of the report.
Unsatisfactory report from someone else? We can quote the repairs.
Engraved, and in writing
No star ratings here. These are the things we put in writing when you book, so you can hold us to them.
The price is fixed first
Confirmed in writing before the visit is booked. From £75.
A qualified inspector
Qualified in inspection and testing, working to the current BS 7671. Ask to see the certificate.
Number on request
The inspector’s scheme number before the visit, so you can check the register.
Photo ID at the door
Your tenant can check who they’re letting in.
The full report in 48 hours
PDF with the schedule of test results, not a one-page summary.
Repairs never pushed
Quoted separately, after the report. Use anyone you like.
How often, by type of property
The 5-year rule is for rentals. Everyone else has a recommended interval rather than a legal one, and the report itself can set a shorter date.
Property
Interval 0 to 10 years
How often
Legal duty?
Where it comes from
Private rental, England
5 yrs
Before a new tenancy if there’s no valid report, then at least every 5 years
S.I. 2020/312, as amended by S.I. 2025/1043
Social housing, England
5 yrs
At least every 5 years
2025 amendment to the same regulations
Rental, Wales
5 yrs
At least every 5 years
Renting Homes (Wales) Act 2016 fitness regulations
Rental, Scotland
5 yrs
At least every 5 years, plus appliance (PAT) checks
Repairing Standard, Housing (Scotland) Act 2006
Rental, Northern Ireland
5 yrs
At least every 5 years
Electrical Safety Standards Regulations (NI) 2024
Owner-occupied home
10 yrs
Every 10 years and on change of occupier
No, recommended
IET guidance
Holiday let
5 yrs*
Many owners follow the 5-year rental interval
No set interval; duty of care applies
Insurer and platform requirements vary
* No set legal interval for holiday lets; many owners follow the 5-year rental interval. The report itself can set a shorter date for any property.
Leave yourself a message
Enter the date of your last report and we’ll write the due date on the pad, with a sensible day to ring about the next one. Save it to your calendar so it doesn’t depend on memory.
Date of the last EICR
dd/mm/yyyy
Interval
Rental: 5 years
60 | Rental: 5 years
120 | Owner-occupied: 10 years
36 | Report said 3 years
12 | Report said 1 year
Property nickname (optional)
e.g. Flat 2, Elm Road
While you were out
Re
EICR
Last report
—
Next due by
—
Ring us from
—
Number
020 3386 1854
Telephoned
Please call back
Will call again
Urgent
Directory enquiries
The questions people ask when they’re looking for an EICR electrician near them.
Can any electrician do an EICR?
Not necessarily. An EICR is a periodic inspection, and the rules for rented homes require a person qualified and competent to inspect and test. Many electricians install but don’t do periodic inspections. Ask for an inspection and testing qualification such as City & Guilds 2391 (or 2394 and 2395) and a competent person scheme registration you can check.
How do I check an electrician near me is registered?
Ask which scheme they’re registered with and for their registration number, then search the Registered Competent Person Electrical register at electricalcompetentperson.co.uk (England and Wales) or the scheme’s own register. Check the business name and address match, and keep a dated screenshot with the report.
How much does an EICR electrician charge?
Our fixed prices are £75 for a studio, £98.99 for a 1–3 bedroom home, £109.99 for 4 bedrooms and £149.99 for 5–6 bedrooms, plus £89.99 for each extra consumer unit. A commercial EICR is £149.99 for up to 10 circuits, and HMOs are priced on the call. The exact figure is confirmed in writing before the visit is booked. Repairs are quoted separately.
How long does an EICR take?
Usually 1.5–2.5 hours for a studio or 1-bed, 2.5–4 hours for a 2–3 bed house, 4–6 hours for 4–5 bedrooms, and half a day to a full day for an HMO. Older wiring, extra consumer units and outbuildings add time.
Will the power be off during the inspection?
Yes, for periods. Most tests are done with circuits switched off one at a time. Let your tenant know about fridges and freezers, broadband, alarms and anything medical, and tell us about any equipment that can’t lose power.
Do I need to be at the property?
No. Your tenant or agent can let the inspector in. They need access to every room, the consumer unit and, where possible, the loft and any outbuildings with electrics. Areas that can’t be reached are recorded as limitations.
What happens if the EICR is unsatisfactory?
Any C1, C2 or FI makes it unsatisfactory. In England, landlords must have the work done within 28 days (or the shorter time on the report) by a qualified person, then send written confirmation to the tenant and council within 28 days of the work.
Can the electrician who did the EICR do the repairs?
Yes, if you choose them. You can also use any other qualified electrician or get a second quote. We quote repairs separately, after the report, and never as a condition of the inspection.
Is an EICR the same as a landlord electrical safety certificate?
Mostly, yes. “Landlord electrical certificate” is the everyday name; the document the law asks for is the Electrical Installation Condition Report. New wiring gets a different document, the Electrical Installation Certificate (EIC).
Does a new tenancy need a new EICR?
Not if the current report is still valid. The installation must have been inspected before the tenancy starts and at least every 5 years. Give the new tenant a copy of the existing report before they move in.
Does an EICR include appliances or PAT testing?
No. An EICR covers the fixed installation: wiring, sockets, switches, light fittings and the consumer unit. Appliance testing is separate. In Scotland, landlords also need PAT checks on appliances they provide, and in England social landlords must have provided equipment checked.
How often should an EICR be done?
At least every 5 years for rented homes in England, Wales, Scotland and Northern Ireland, or sooner if the report says so. For owner-occupied homes the IET recommends every 10 years and when the occupier changes.
Book the line, get a fixed price
Three short steps and we’ll call you back with the fixed price and to confirm a date. If you’d rather talk now, ring the number.
Your request so far
Property
Not chosen yet
Fixed price band
—
You are
Landlord
Postcode
—
Preferred visit
—
Fixed in writing before booking · report within 48 hours · repairs quoted separately
Request a fixed price
We only use your details to answer this request.
Where is it, and when would suit you?
Who should we call back?
Next: your visit
Next: your details
Back
Please choose the property size.
Please enter the full property postcode, like LS6 2AB.
Please add your full name.
Please add a phone number we can call back.
Please add a valid email address.
Please add the property address.
Please choose a preferred inspection date.
Please choose today or a later date.
Please choose a preferred inspection time.
This is your preference. We’ll confirm the date and time when we call.